CRYOGENIC
Type 03323 - Actuated Globe Valve
Cryogenic-Globe Valves with Pneumatic Actuator, class 150

Stainless steel body and topwork Actuator - air opens, spring closes or contrary "live loaded" gland packing "cleaned and degreased for oxygen service" - the actuator is not cleaned and degreased for oxygen

Part No. 03323.X.*011

Flanged connection acc. to ASME B16.5 class 150 Available accessories:

- Solenoid valve
- Limit switch
- Electropneumatic positioner etc.

Available options - on request only:
- Actuator - "cleaned and degreased for oxygen service"
- Electric actuator
- Valve with check disc
- Valve with control disc (tapered design)



Applications:
Approved for air gases, vapours and cryogenic liquefied gases incl. LNG.
Working temperature: -196°C / -321°F (77K) up to +120°C / +248°F (393K)

 
Type 03323 - Actuated Globe Valve
 

Materials

DIN EN

ASTM

1 Body 1.4308 A 351 CF8
2 Valve seal up to DN50 PTFE / Carbon filled (25%)
2a Valve seal from DN65 PTFE
3 Disc CW614N B 283 UNS C38500
4 Bonnet gasket PTFE
5 Headpiece 1.4301 A 276 Grade 304
6 Bolts 1.4301/A2 A 194 B8
7 Elongation tube 1.4541 A 213 TP 321
8 Stem 1.4301 A 276 Grade 304
9 Gland packing Graphite / PTFE / MICA
10 Gland nut CW614N B 283 UNS C38500
11 Pillars 1.4404 A 276 Grade 316L
12 Bush CW452K B 159 UNS C51900

 
Type 03323 - Actuated Globe Valve
 

Type 03323 - Standard designTechnical data
Nominal size DN15202540506580100150
Dimension code - Flange ASME B16.5 class 150.X.040006001000140020002400300040006000
Flange-ØD-class90100110125150180190230280
Face-to-face dimensionFF140150160200230290310350577
HeightH370370375420425510575635685
LengthE195200200230235300300300350
Actuator-ØMdependent on actuator
Wrench size across flatsS2 303030363636364141
Weight w/o actuatorca. kg4.66.58.512.016.030.036.053.087.0
*Kvs-Valuem³/h4.36.711.522.637.171.1104.0170.0350.0
*Cv-Valuegal/min5.07.813.426.343.282.9121.3198.3408.4
Strokemm1079111523233040
Dimensions in mm. Compliance of tightness requirements acc. to EN 1626 for DN150 up to 20 bar differential pressure. In the range of >20-40 bar, 350-700ml per second (1 bar, 20°C [68°F]) are reached. * These figures refer to measurements for the flow direction.