CRYOGENIC
Type 27100 - Electric Actuator
Overview - required actuator sizes for differential pressures
|
Electric Actuators for Globe and Control Valves mechanical position indicator, with emergency handwheel, protection class IP 65 (DIN VDE 0470) power supply 24 V, 115 V, 230 V, 50/60 Hz, (please indicate on purchase order) Mounting position: considering the mounting position of the valve For outdoor installation or high humidity, we recommend the use of two heatings Part No. 27100.0030.*02800 2x force switch - directly wired, 2x limit switch - directly wired Part No. 27100.0060.*04500 2x force switch - directly wired, 2x limit switch - directly wired Part No. 27100.0100.*09000 2x force switch - directly wired, 2x limit switch - directly wired * AC=alternating current, *DC=direct current Ambient temperature limit: -20°C / -4°F (253K) up to +70°C / +158°F (343K)
|
|
|||||||||||||
|
|
|
|||||||||||||
Overview - required actuator sizes for differential pressures
| DN | Differential pressure in bar | |||||||||
| 1.00
- 5.00 | 5.01
- 7.00 | 7.01
- 10.00 | 10.01
- 13.00 | 13.01
- 20.00 | 20.01
- 25.00 | 25.01
- 33.00 | 33.01
- 40.00 | 40.01
- 46.01 | 46.01
- 50.00 | |
| 10 | A | A | A | A | A | A | A | A | A | A |
| 15 | A | A | A | A | A | A | A | A | A | A |
| 20 | A | A | A | A | A | A | A | A | A | A |
| 25 | A | A | A | A | A | A | A | A | B | B |
| 32 | A | A | A | A | A | A | B | B | B | B |
| 40 | A | A | A | A | A | B | B | B | C | C |
| 50 | A | A | A | A | B | B | C | C | C | - |
| 65 | A | A | A | B | C | C | - | - | - | - |
| 80 | B | B | B | C | - | - | - | - | - | - |
| 100 | B | B | C | - | - | - | - | - | - | - |
| Code in Table | Part No. Actuator | |
| A | 27100.0030.*02800 | |
| B | 27100.0060.*04500 | |
| C | 27100.0100.*09000 | |
| Type 27100 | Technical Data | |||
| Part No. Actuator: | ||||
| .0030.*02800 | .0060.*04500 | .0100.*09000 | ||
| Diameter | M | 177 | 177 | 177 |
| Diameter | M1 | 262 | 262 | 262 |
| Operational force | kN | 2.8 | 6.0 | 10.0 |
| Operational speed | mm/s | 0.28 | 0.45 | 0.90 |
| Power consumption | VA | 12 (10VADC) | 46 (18VADC) | 81 (41VADC) |
| Cable glands | 4x M20 | 4x M20 | 4x M20 | |
| Height | H | 327 | 393 | 393 |
| Height | H1 | 233 | 233 | 233 |
| Height | h | 120 | 120 | 120 |
| Weight | ca. kg | 4.5 | 6.7 | 6.7 |
| Stroke | mm | 40 | 40 | 40 |
| Dimensions in mm. |