CRYOGENIC
Type 27521 - Pneumatic Actuator - Globe Valve (on/off)
Pneumatic Actuators for Globe Valves (on/off)

Actuator - air to open,
spring to close
maximum air pressure for operation 6.0 bar g
"cleaned and degreased for oxygen service"
Ambient temperature limit:

-40°C / -40°F (233K) up to +80°C / 176°F (353K)


The differential pressures are based on the flow direction of the valve. Differential pressures against the flow direction have to be requested separately.

 
Type 27521 - Pneumatic Actuator - Globe Valve (on/off)
 

Materials

DIN EN

ASTM

1 Body 1.4571 A 240 Grade 316Ti
2 Body 1.4571 A 240 Grade 316Ti
3 Diaphragm EPDM
4 Springs 1.7102 AISI 9254
5 Actuator stem 1.4404 A 276 Grade 316L
6 Coupling 1.4571 A 240 Grade 316Ti
 
Type 27521 - Pneumatic Actuator - Globe Valve (on/off)
 

Overview - required actuator sizes for differential pressures

DNDifferential pressure in bar
1.0
-
3.0
3.1
-
4.0
4.1
-
7.0
7.1
-
10.0
10.1
-
11.0
11.1
-
15.0
15.1
-
18.0
18.1
-
20.0
20.1
-
22.0
22.1
-
30.0
30.1
-
33.0
33.1
-
35.0
35.1
-
50.0
10BBBBBBBBBBBBB
15BBBBBBBBBBBBB
20BBBBBBBBBBBBB
25BBBBBBBBBBBBB
32BBBBBBBBBBBBC
40BBBBBBBBBCCCC
50BBBBBBCCCCCC-
65BBBCCCC------
80BBCC---------
100B------------
150-------------


Code in TablePart No. Actuator
B27521.35B6.6GPO
C27521.60A6.6GPO



Type 27521Technical data
Part No. Actuator27521
.35B6.6GPO.60A6.6GPO
Diameter ActuatorM210310
HeightH276309
HeightH1136166
ThreadG1/4'' NPT1/4'' NPT
Diaphragm areacm²280530
Spring ragebar0.8 - 3.00.8 - 2.8
Minimum air pressurebar3.23.0
Regulating liftmm3540
Weightca. kg5.012.5
Dimensions in mm.