CRYOGENIC
Type 27522 - Pneumatic Actuator - Control Valve
Overview - required actuator sizes for differential pressures
|
Pneumatic Actuators for Control Valves Actuator - spring to open , air to close maximum air pressure for operation 6.0 bar g "cleaned and degreased for oxygen service" Ambient temperature limit: -40°C / -40°F (233K) up to +80°C / 176°F (353K) The differential pressures are based on the flow direction of the valve. Differential pressures against the flow direction have to be requested separately. |
|
|||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||
Overview - required actuator sizes for differential pressures
| DN | Differential pressure in bar | ||||||||
| 1.0
- 5.0 | 5.1
- 13.0 | 13.1
- 15.0 | 15.1
- 21.0 | 21.1
- 23.0 | 23.1
- 29.0 | 29.1
- 34.0 | 34.1
- 37.0 | 37.1
- 50.0 | |
| 10 | B | B | B | B | B | B | B | B | B |
| 15 | B | B | B | B | B | B | B | B | B |
| 20 | B | B | B | B | B | B | B | B | B |
| 25 | B | B | B | B | B | B | B | B | B |
| 32 | B | B | B | B | B | B | B | B | C |
| 40 | B | B | B | B | B | B | B | C | C |
| 50 | C | C | C | C | C | C | C | C | C |
| 65 | C | C | C | C | C | C | - | - | - |
| 80 | C | C | C | C | - | - | - | - | - |
| 100 | C | C | - | - | - | - | - | - | - |
| 150 | - | - | - | - | - | - | - | - | - |
| Code in Table | Part No. Actuator | |
| B | 27522.35B6.6GPS | |
| C | 27522.60A6.6GPS | |
| Type 27522 | Technical data | ||
| Part No. Actuator | 27522 | ||
| .35B6.6GPS | .60A6.6GPS | ||
| Diameter Actuator | M | 210 | 310 |
| Height | H | 276 | 309 |
| Height | H1 | 136 | 166 |
| Thread | G | 1/4'' NPT | 1/4'' NPT |
| Diaphragm area | cm² | 280 | 530 |
| Spring rage | bar | 0.8 - 3.0 | 0.8 - 2.8 |
| Minimum air pressure | bar | 6.0 | 6.0 |
| Regulating lift | mm | 35 | 40 |
| Weight | ca. kg | 5.0 | 12.5 |
| Dimensions in mm. |
- Type 41060 - Solenoid Valve
- Type 41060 - Solenoid Valve, suitable for oxygen
- Type 41061 - Solenoid Valve EEx
- Type 41070, 41071 - Position and Limit Switches
- Type 41080 - Inductive Proximity Switches
- Type 41281 - Inductive Proximity Switches EEx-Box
- Type 41090 - Electropneumatic Positioner
- Type 41090 - Pneumatic Positioner
- Type 41091 - Electropneumatic Positioner EEx
- Type 08003 - Air Control Sets