CRYOGENIC
Type 27522 - Pneumatic Actuator - Control Valve
Pneumatic Actuators for Control Valves

Actuator -
spring to open
, air to close maximum air pressure for operation 6.0 bar g
"cleaned and degreased for oxygen service"
Ambient temperature limit:

-40°C / -40°F (233K) up to +80°C / 176°F (353K)


The differential pressures are based on the flow direction of the valve. Differential pressures against the flow direction have to be requested separately.

 
Type 27522 - Pneumatic Actuator - Control Valve
 

Materials

DIN EN

ASTM

1 Body 1.4571 A 240 Grade 316Ti
2 Body 1.4571 A 240 Grade 316Ti
3 Diaphragm EPDM
4 Springs 1.7102 AISI 9254
5 Actuator stem 1.4404 A 276 Grade 316L
6 Coupling 1.4571 A 240 Grade 316Ti
 
Type 27522 - Pneumatic Actuator - Control Valve
 

Overview - required actuator sizes for differential pressures

DNDifferential pressure in bar
1.0
-
5.0
5.1
-
13.0
13.1
-
15.0
15.1
-
21.0
21.1
-
23.0
23.1
-
29.0
29.1
-
34.0
34.1
-
37.0
37.1
-
50.0
10BBBBBBBBB
15BBBBBBBBB
20BBBBBBBBB
25BBBBBBBBB
32BBBBBBBBC
40BBBBBBBCC
50CCCCCCCCC
65CCCCCC---
80CCCC-----
100CC-------
150---------


Code in TablePart No. Actuator
B27522.35B6.6GPS
C27522.60A6.6GPS



Type 27522Technical data
Part No. Actuator27522
.35B6.6GPS.60A6.6GPS
Diameter ActuatorM210310
HeightH276309
HeightH1136166
ThreadG1/4'' NPT1/4'' NPT
Diaphragm areacm²280530
Spring ragebar0.8 - 3.00.8 - 2.8
Minimum air pressurebar6.06.0
Regulating liftmm3540
Weightca. kg5.012.5
Dimensions in mm.