CRYOGENIC
Type T118 - Globe Valve
|
Cryogenic Globe Valves with check unit, PN50 suitable for CombiPressure-Regulator type 4182/4186 "cleaned and degreased for oxygen service" Part No. T118.X.1A0C0 Male thread for union connection Available options - on request only: - Butt weld connection for stainless steel pipes acc. to ISO 1127 or ASTM A312 - Union type butt weld fittings for stainless steel pipes acc. to ISO 1127 or ASTM A312 - Union type braze fittings for copper pipes acc. to DIN EN 12449 or ASTM B88 - Thread connection NPT acc. to ANSI B 1.20.1
Applications: Approved for air gases, vapours and cryogenic liquefied gases incl. LNG. Working temperature: -196°C / -321°F (77K) up to +65°C / 149°F (338K) Ambient temperature: -40°C / -40°F (233K) up to +65°C / 149°F (338K) Maximum operating pressure: 50bar |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Type T118 | Technical data | |
| Nominal size | DN | 20 |
| Dimension code | .X. | FM02615 |
| Height | H | 97 |
| Thread | GA | M40x2.0 |
| Thread | GW | M26x1.5 |
| Weight | ca. kg | 0.7 |
| Kvs-Value | m³/h | 2.0 |
| Cv-Value | gal/min | 2.3 |
| Dimensions in mm. |