- Home
- › Products
- › Cryogenic
- › Actuated Valves
CRYOGENIC
Type 01643 - Actuated Globe Valve
Cryogenic-Globe Valves with Pneumatic Actuator, PN50 (DN150=PN40) “Fire safe” type test approval acc. to EN ISO 10497 Stainless steel body and topwork Actuator - air opens, spring closes “live loaded” gland packing “cleaned and degreased for oxygen service" - the actuator is not cleaned and degreased for oxygen Part No. 01643.X.*01* * Butt weld connection for stainless steel pipes acc. to ISO 1127 or ASTM A312 Part No. 01643.X.*014 Socket weld connection for stainless steel pipes acc. to ISO 1127 or ASTM A312 Available accessories: - Solenoid valve - Limit switch - Electropneumatic positioner etc. Available options - on request only: - Welded stainless steel stubs acc. to ISO 1127 or ASTM A312 - length FF + 200mm - Actuator “cleaned and degreased for oxygen sevice” Applications: Approved for air gases, vapours and cryogenic liquefied gases incl. LNG. Working temperature: -196°C / -321°F (77K) up to +120°C / +248°F (393K) |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
Type 01643 - Standard design | Technical data | |||||||||||||
Nominal size | DN | 10 | 15 | 15 | 20 | 25 | 32 | 40 | 40 | 50 | 65 | 80 | 100 | 150 |
Dimension code | .X. | 1012 | 1517 | 1521 | 2026 | 2533 | 3238 | 4042 | 4048 | 5060 | 657x | 8088 | 0114 | 0168 |
Face-to-face dimension | FF | 70 | 85 | 85 | 100 | 115 | 115 | 130 | 130 | 155 | 205 | 245 | 280 | 400 |
Height | H | 370 | 370 | 370 | 370 | 375 | 405 | 420 | 420 | 425 | 510 | 575 | 635 | 685 |
Length | E | 195 | 195 | 195 | 200 | 200 | 230 | 230 | 230 | 235 | 300 | 300 | 300 | 300 |
Outside pipe-Ø ISO 1127 | RA | 12.0 | 17.2 | 21.3 | 26.9 | 33.7 | 38.0 | 42.4 | 48.3 | 60.3 | 76.1 | 88.9 | 114.3 | 168.3 |
Wall thickness pipe ISO 1127 | a | 1.0 | 1.6 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.9 | 3.2 | 6.0 | 7.1 |
Outside pipe-Ø ASTM A312 | RA | 13.72 | 17.15 | 21.34 | 26.67 | 33.40 | - | 42.16 | 48.26 | 60.33 | 73.03 | 88.90 | 114.3 | 168.3 |
Wall thickness pipe ASTM A312 | a | dimensions acc. to S10 or S40 | ||||||||||||
Socket depth | b | 6 | 10 | 10 | 13 | 13 | - | 13 | 13 | 16 | 16 | 16 | 20 | 20 |
Actuator-Ø | M | dependent on actuator | ||||||||||||
Wrench size across flats | S2 | 30 | 30 | 30 | 30 | 30 | 36 | 36 | 36 | 36 | 36 | 36 | 41 | 41 |
Weight w/o actuator | ca. kg | 1.9 | 2.15 | 2.2 | 2.4 | 3.1 | 3.8 | 6.5 | 6.5 | 9.0 | 15.2 | 20.0 | 28.0 | 60.9 |
*Kvs-Value | m³/h | 1.6 | 3.8 | 4.3 | 6.7 | 11.5 | 14.0 | 20.6 | 22.6 | 37.1 | 71.1 | 104.0 | 170.0 | 350.0 |
*Cv-Value | gal/min | 1.9 | 4.4 | 5.0 | 7.8 | 13.4 | 16.2 | 23.9 | 26.3 | 43.2 | 82.9 | 121.3 | 198.3 | 408.4 |
Stroke | mm | 10 | 10 | 10 | 7 | 9 | 9 | 11 | 11 | 15 | 23 | 23 | 30 | 40 |
Dimensions in mm. Compliance of tightness requirements acc. to EN 1626 for DN150 up to 20 bar differential pressure. In the range of >20-40 bar, 350-700ml per second (1 bar, 20°C [68°F]) are reached. * These figures refer to measurements for the flow direction. |
- CE approval
- TPED approval
- DIN EN 12567 / 10497 approval
- ABS approval
- BV approval
- CCS approval
- DNV approval
- LR approval
- RINA approval
- RMRS approval
- ClassNK approval
- UKCA approval
- Installation/operating instruction
- Conformity declaration (CE)
- Conformity declaration
- Conformity declaration (Pi)
- Conformity declaration (SIL)