CRYOGENIC
Type 27511 - Pneumatic Actuator - Control Valve
 
Overview - required actuator sizes for differential pressures
| 
Pneumatic Actuators for Control Valves Actuator - air to open, spring to close maximum air pressure for operation 6.0 bar g Actuator coating outside - Epoxy resin Available options - on request only: - Pneumatic actuator with override handwheel Ambient temperature limit: -20°C / -4°F (253K) up to +80°C / 176°F (353K) The differential pressures are based on the flow direction of the valve. Differential pressures against the flow direction have to be requested separately.  | 
  | 
|||||||||||||||||||||||||||||||
  | 
  | 
|||||||||||||||||||||||||||||||
Overview - required actuator sizes for differential pressures
| DN | Differential pressure in bar | |||||||||||||||
| 1.0
 - 2.0  | 2.1
 - 4.0  | 4.1
 - 6.0  | 6.1
 - 8.0  | 8.1
 - 10.0  | 10.1
 - 12.0  | 12.1
 - 15.0  | 15.1
 - 17.0  | 17.1
 - 19.0  | 19.1
 - 22.0  | 22.1
 - 25.0  | 25.1
 - 29.0  | 29.1
 - 35.0  | 35.1
 - 39.0  | 39.1
 - 42.0  | 42.1
 - 50.0  | |
| 10 | A | A | A | A | A | A | A | A | A | A | A | A | A | A | A | A | 
| 15 | A | A | A | A | A | A | A | A | A | A | A | A | A | A | A | A | 
| 20 | A | A | A | A | A | A | A | A | A | A | A | B | B | B | B | B | 
| 25 | A | A | A | A | A | A | A | A | B | B | B | B | B | B | B | C | 
| 32 | B | B | B | B | B | B | B | B | B | B | C | C | C | C | C | C | 
| 40 | B | B | B | B | B | B | B | C | C | C | C | C | C | C | D | D | 
| 50 | B | B | B | B | B | C | C | C | C | C | C | D | D | E | E | E | 
| 65 | C | C | C | C | C | C | D | E | E | E | E | E | F | F | F | G | 
| 80 | C | C | C | D | E | E | E | E | F | F | F | F | G | G | o.r. | |
| 100 | C | C | D | E | E | F | F | F | F | G | G | o.r. - on request | ||||
| 150 | D | E | F | F | G | o.r. - on request | ||||||||||
| Code in Table | Part No. Actuator | |
| A | 27511.15A6.3SPO | |
| B | 27511.35B6.6GPO | |
| C | 27511.60A6.6GPO | |
| D | 27511.60C6.7GPO | |
| E | 27511.75B6.3DPO | |
| F | 27511.75B6.5DPO | |
| G | 27511.75B6.7DPO | |
| Type 27511 | Technical data | |||||||
| Part No. Actuator | 27511 | |||||||
| .15A6.3SPO | .35B6.6GPO | .60A6.6GPO | .60C6.7GPO | .75B6.3DPO | .75B6.5DPO | .75B6.7DPO | ||
| Diameter Actuator | M | 162 | 210 | 310 | 310 | 430 | 430 | 430 | 
| Height | H | 256 | 276 | 309 | 352 | 353 | 353 | 353 | 
| Height | H1 | 116 | 136 | 166 | 186 | 234 | 234 | 234 | 
| Thread | G | G1/8'' with Ermeto-Fitting L8 | - | - | - | - | - | - | 
| Thread | G1 | - | 1/4'' NPT | 1/4'' NPT | 1/4'' NPT | 1/4'' NPT | 1/4'' NPT | 1/4'' NPT | 
| Diaphragm area | cm² | 120 | 280 | 530 | 530 | 1000 | 1000 | 1000 | 
| Spring range | bar | 0.9 - 2.0 | 0.8 - 3.0 | 0.8 - 2.8 | 0.7 - 3.0 | 0.7 - 2.1 | 1.2 - 3.4 | 1.6 - 4.7 | 
| Minimum air pressure | bar | 2.2 | 3.2 | 3.0 | 3.2 | 2.3 | 3.6 | 4.9 | 
| Regulating lift | mm | 20 | 35 | 40 | 60 | 60 | 60 | 60 | 
| Weight | ca. kg | 3.0 | 5.0 | 12.5 | 14.0 | 37.0 | 39.0 | 41.0 | 
| Dimensions in mm. | 
	
- Type 41060 - Solenoid Valve
 - Type 41060 - Solenoid Valve, suitable for oxygen
 - Type 41061 - Solenoid Valve EEx
 - Type 41070, 41071 - Position and Limit Switches
 - Type 41080 - Inductive Proximity Switches
 - Type 41281 - Inductive Proximity Switches EEx-Box
 - Type 41090 - Electropneumatic Positioner
 - Type 41090 - Pneumatic Positioner
 - Type 41091 - Electropneumatic Positioner EEx
 - Type 08003 - Air Control Sets
 