CRYOGENIC
Type 27514 - Pneumatic Actuator - Globe Valve (On/off and Control Valve)
Pneumatic Actuators for Type 11C01 - Globe Valve FullX
Actuator - spring to close, air to open maximum air pressure for operation 6.0 bar Actuator coating: Delta Seal GZ (silver-grey) Corrosion-protection class C5-M acc. to DIN EN ISO 12944

Available options - on request only:

- Pneumatic actuator with override handwheel Ambient temperature limit: -40°C / -40°F (233K) up to +100°C / 212°F (373K)


The differential pressures are based on the flow direction of the valve. Differential pressures against the flow direction have to be requested separately.

 
Type 27514 - Pneumatic Actuator - Globe Valve (On/off and Control Valve)
 

Materials

DIN EN

ASTM

1 Body 1.0335 A 622 Grade 1008
2 Diaphragm NBR + tissue
3 Springs 1.4310 A 313 Grade 301
4 Actuator stem 1.4571 A 276 Grade 316Ti
5 Coupling 1.4571 A 276 Grade 316Ti
 
Type 27514 - Pneumatic Actuator - Globe Valve (On/off and Control Valve)
 

Overview - required actuator sizes for differential pressures


Type 27514Technical Data
Part No. Actuator 27514
.DP30 .2O22.DP32 .2O08.DP32 .2O20.DP33 .3O20.DP34 .5O15.DP34 .5O20.DP34 .T0PO.DP34 .TRPO.DP34 .TRP1
Diameter ActuatorM168250250300405405405405405
HeightHca. 244ca. 240ca. 240ca. 300ca. 375ca. 375ca. 635ca. 884ca. 884
HeightH1122124124166228228450672672
ThreadGG 1/4"G 1/4''G 1/4''G 1/4''G 3/8''G 3/8''G 3/8''G 1/2"G 1/2"
Diaphragm areacm²802502504008008001600 (2x800)2400 (3x800)2400 (3x800)
Spring rangebar2.2 - 4.50.8 - 2.42.0 - 3.82.0 - 4.01.5 - 3.02.0 - 4.02.0 - 4.02.0 - 4.02.0 - 4.0
Minimum air pressurebar4.82.73.64.53.34.54.54.54.5
Regulating liftmm202020305050506565
Weightca. kg5.09.09.015.045.045.0116.0150.0152.0
Dimensions in mm.



Overview - required actuator sizes for differential pressures


DNBody**Differential pressure in bar
1,0 - 5,96,0 - 9,910,0 - 15,916,0 - 29,930,0 - 35,936,0 - 37,938,0 - 43,944,0 - 49,950,0 - 53,954,0 - 63,0
10S/A/YAAAAAAAAAA
15S/A/YAAAAAAAAAA
20S/A/YAAAAABBBBC
25S/A/YAAAAABBBBC
32      SBBCCDDDDDD
32   A/YEEEEEEEEEE
40      SBBCCDDDDDD
40   A/YEEEEEEEEEE
50      SBCCDDDDDEE
50   A/YEEEEEEEEEE
           
10*S/A/YAAAAAAABBB
15*S/A/YAAAAAAABBB
20*S/A/YAAAAAABBBB
25*S/A/YAAAAAABBBB
32*S/A/YBBCCDDDDDD
40*S/A/YBBCCDDDDDD
50*S/A/YBCCDDDDDEE
* with bellows or control version or throttle version, ** S = Straight body, A = Angle type, Y = Y type 


The differential pressures are based on the flow direction of the valve.
Differential pressures against the flow direction have to be requested separately.


Code in TablePart-No. Actuator
A27514.DP30.2O22
B27514.DP32.2O08
C27514.DP32.2O20
D27514.DP33.3O20
E27514.DP34.5O15