CRYOGENIC
Type 27515 - Pneumatic Actuator - Globe Valve (on/off)
Overview - required actuator sizes for differential pressures
Pneumatic Actuators for Globe Valves (on/off) Actuator - spring to open , air to close maximum air pressure for operation 6.0 bar Actuator coating: Delta Seal GZ (silver-grey) Corrosion-protection class C5-M acc. to DIN EN ISO 12944 Available options - on request only: - Pneumatic actuator with override handwheel Ambient temperature limit: -40°C / -40°F (233K) up to +100°C / 212°F (373K) The differential pressures are based on the flow direction of the valve. Differential pressures against the flow direction have to be requested separately. |
|
|||||||||||||||||||||||||||
|
|
Overview - required actuator sizes for differential pressures
DN | Differential pressure in bar | ||||||
1.0
- 13.0 | 13.1
- 18.0 | 18.1
- 20.0 | 20.1
- 25.0 | 25.1
- 35.0 | 35.1
- 45.0 | 45.1
- 50.0 | |
10 | A | A | A | A | A | A | A |
15 | A | A | A | A | A | A | A |
20 | A | A | A | A | A | A | A |
25 | A | A | A | A | A | A | B |
32 | A | A | A | A | B | B | B |
40 | A | A | A | B | B | B | B |
50 | A | B | B | B | B | B | B |
65 | B | B | B | B | B | C | C |
80 | B | B | B | C | C | D | D |
100 | B | C | C | D | D | D | o.r. |
150 | D | D | D | o.r. - on request |
Code in Table | Part No. Actuator | |
A | 27515.DP30.2S06 | |
B | 27515.DP32.3S02 | |
C | 27515.DP33.3S02 | |
D | 27515.DP34.5S02 |
Type 27515 | Technical data | ||||
Part No. Actuator | 27515 | ||||
.DP30.2S06 | .DP32.3S02 | .DP33.3S02 | .DP34.5S02 | ||
Diameter Actuator | M | 168 | 250 | 300 | 405 |
Height | H | ca. 244 | ca. 240 | ca. 300 | ca. 375 |
Height | H1 | 122 | 124 | 166 | 228 |
Thread | G | G 1/4" | G 1/4'' | G 1/4'' | G 3/8'' |
Diaphragm area | cm² | 80 | 250 | 400 | 800 |
Spring range | bar | 0.6 - 1.5 | 0.2 - 1.0 | 0.2 - 1.0 | 0.2 - 1.0 |
Minimum air pressure | bar | 6.0 | 6.0 | 6.0 | 6.0 |
Regulating lift | mm | 20 | 30 | 30 | 50 |
Weight | ca. kg | 5.0 | 9.0 | 15.0 | 45.0 |
Dimensions in mm. |
- Type 41060 - Solenoid Valve
- Type 41060 - Solenoid Valve, suitable for oxygen
- Type 41061 - Solenoid Valve EEx
- Type 41070, 41071 - Position and Limit Switches
- Type 41080 - Inductive Proximity Switches
- Type 41281 - Inductive Proximity Switches EEx-Box
- Type 41090 - Electropneumatic Positioner
- Type 41090 - Pneumatic Positioner
- Type 41091 - Electropneumatic Positioner EEx
- Type 08003 - Air Control Sets