Type 01473 - Actuated Globe Valve
Top Entry Cryogenic-Globe Valves with Pneumatic Actuator, PN50 (DN100=PN40) Stainless steel body and topwork "live loaded" gland packing "cleaned and degreased for oxygen service" - the actuator is not cleaned and degreased for oxygen Part No. 01473.X.3081 Butt weld connection for stainless steel pipes acc. to ISO 1127 or ASTM A312 Available accessories/options - on request only: - Solenoid valve - Limit switch - Electropneumatic positioner etc. - Extension H and A acc. to customer specification - Actuator "cleaned and degreased for oxygen service" - Valve with check disc, valve with control disc (tapered design) Applications: Approved for hydrogen, air gases, vapours and cryogenic liquefied gases incl. LNG. Working temperature: -255°C / -427°F (18K) up to +120°C / +248°F (393K) |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
Type 01473 - Standard design | Technical data | |||
Nominal size | DN | 65 | 80 | 100 |
Dimension code | .X. | 6573 | 8088 | 0114 |
Face-to-face dimension | FF | 205 | 245 | 280 |
Height | H | 1105 | 1110 | 1290 |
Actuator-Ø | B | dependent on actuator | ||
Outside pipe-Ø ASTM A312 | RA | 73.00 | 89.00 | 114.30 |
Wall thickness pipe ASTM A312 | a | dimensions acc. to S10 or S40 | ||
Length | A | 610 | 640 | 750 |
Length | G | acc. to customer specification | ||
Length | M | acc. to customer specification | ||
Wrench size across flats | S2 | 41 | 41 | 41 |
Stroke | mm | 23 | 23 | 30 |
Weight without actuator | ca. kg | 28.3 | 34.3 | 49.2 |
*Kvs-Value | m³/h | 71.1 | 104.0 | 168.0 |
*Cv-Value | gal/min | 82.9 | 121.3 | 196.0 |
Dimensions in mm. * These figures refer to measurements for the flow direction. |