Type 05419 - Check Valve, DIN EN Flanges
|
Cryogenic-Check Valves, PN40 Stainless steel body and cap with spring, opening pressure ca. 0.1 bar "cleaned and degreased for oxygen service" Part No. 05419.X.0002 Flanged connection acc. to DIN EN 1092-1 PN40 Check valves provide reliable backflow functionality when properly sized. Based on experience, the minimum operating range of the valve should be 50% for gases and 40% for liquids in relation to the total capacity of the valve. Lower flow rates can lead to unstable performance, excessive noise, and even component failure. Applications: Approved for air gases, vapours and cryogenic liquefied gases incl. LNG. Working temperature: -196°C / -321°F (77K) up to +120°C / +248°F (393K) |
|
||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||
| Type 05419 - Standard design | Technical data | |||||||||
| Nominal size | DN | 15 | 20 | 25 | 40 | 50 | 65 | 80 | 100 | 150 |
| Dimension code - Flange EN 1092-1 PN40 | .X. | 0150 | 0200 | 0250 | 0400 | 0500 | 0650 | 0800 | 1000 | 1500 |
| Flange-Ø | D-PN | 95 | 105 | 115 | 150 | 165 | 185 | 200 | 235 | 300 |
| Face-to-face dimension | FF | 140 | 150 | 160 | 200 | 230 | 290 | 310 | 350 | 550 |
| Height | H | 70 | 75 | 75 | 95 | 90 | 125 | 150 | 165 | 215 |
| Weight | ca. kg | 2.9 | 3.4 | 4.4 | 6.4 | 11.6 | 19.2 | 25.2 | 39.8 | 72.7 |
| Kvs-Value | m³/h | 4.3 | 6.7 | 11.5 | 22.6 | 37.1 | 71.1 | 104.0 | 170.0 | 350.0 |
| Cv-Value | gal/min | 5.0 | 7.8 | 13.4 | 26.3 | 43.2 | 82.9 | 121.3 | 198.3 | 408.4 |
| Dimension in mm. Leakage rates will be provided on request |