Type 01342 - Globe Valve Angle Type
Cryogenic-Globe and Globe/Check Valves, PN50 Stainless steel body and topwork, "live loaded" gland packing "cleaned and degreased for oxygen service" Part No. 01342.X.001* (H = 270mm) Part No. 01342.X.002* (H = 370mm) * Butt weld connection for stainless steel pipes acc. to ISO 1127 or ASTM A312 Part No. 01342.X.0014 (H = 270 mm) Part No. 01342.X.0024 (H = 370 mm) Socket weld connection for stainless steel pipes acc. to ISO 1127 or ASTM A312 Available options - on request only: - Extension H up to 900mm - Valve with control disc (tapered design) - Valve with check disc - Further pipe wall thicknesses Applications: Approved for air gases, vapours and cryogenic liquefied gases incl. LNG. Working temperature: -196°C / -321°F (77K) up to +120°C / +248°F (393K) |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
Type 01342 - Standard design | Technical data | ||||||
Nominal size | DN | 15 | 20 | 25 | 32 | 40 | 50 |
Dimension code | .X. | 1521 | 2026 | 2533 | 3242 | 4048 | 5060 |
Face-to-face dimension | FF | 40 | 50 | 55 | 60 | 58 | 85 |
Height | H | 270 mm or 370 mm | |||||
Outside pipe-Ø ISO 1127 | RA | 21.3 | 26.9 | 33.7 | 42.0 | 48.3 | 60.3 |
Wall thickness pipe ISO 1127 | a | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 |
Outside pipe-Ø ASTM A312 | RA | 21.34 | 26.67 | 33.4 | - | 48.26 | 60.33 |
Wall thickness pipe ASTM A312 | a | dimensions acc. to S10 or S40 | |||||
Socket depth | b | 10 | 13 | 13 | 13 | 13 | 16 |
Handwheel-Ø | B | 100 | 100 | 100 | 125 | 125 | 125 |
Length | L | 50 | 65 | 80 | 80 | 90 | 90 |
Wrench size across flats | S1 | 7 | 7 | 7 | 10 | 10 | 10 |
Wrench size across flats | S2 | 30 | 30 | 30 | 36 | 36 | 36 |
Weight | ca. kg | 1.4 | 1.6 | 2.2 | 4.0 | 4.3 | 6.5 |
Kvs-Value | m³/h | 6.0 | 10.5 | 17.2 | 32.0 | 35.0 | 57.0 |
Cv-Value | gal/min | 7.0 | 12.2 | 20.0 | 37.2 | 40.7 | 66.3 |
Dimensions in mm. |