CRYOGENIC
Type 01352 - Globe Valve Angle Type
Cryogenic-Globe Valves Angle Type, PN50

Stainless steel body and topwork, "live loaded" gland packing "cleaned and degreased for oxygen service"


Part No. 01352.X.000*

* Butt weld connection for stainless steel pipes acc. to ISO 1127 or ASTM A312
Part No. 01352.X.0004
Socket weld connection for stainless steel pipes acc. to ISO 1127 or ASTM A312

Available options - on request only:

- Valve with control disc (tapered design)
- Valve with check disc
- Further pipe wall thicknesses


Applications:
Approved for air gases, vapours and cryogenic liquefied gases incl. LNG.
Working temperature: -196°C / -321°F (77K) up to +120°C / +248°F (393K) Recommended working temperature: -60°C / -76°F (213K) up to +120°C / +248°F (393K)

 
Type 01352 - Globe Valve Angle Type
 

Materials

DIN EN

ASTM

1 Body 1.4308 A 351 CF8
2 Valve seal PTFE / Carbon filled (25%)
3 Disc 1.4301 A 276 Grade 304
4 Bonnet gasket PTFE
5 Headpiece 1.4301 / 1.4308 A 276 Grade 304 / A 351 CF8
6 Bolts 1.4301/A2 A 194 B8
8 Stem 1.4301 A 276 Grade 304
9 Gland packing Graphite / PTFE / MICA
10 Gland nut 1.4305 A 276 Grade 303
11 Handwheel Aluminium alloy
13 Bush CW452K B 159 UNS C51900

 
Type 01352 - Globe Valve Angle Type
 

Type 01352 - Standard designTechnical data
Nominal size DN152025324050
Dimension code.X.152120262533324240485060
Face-to-face dimensionFF405055605885
HeightH140140140170175200
Outside pipe-Ø ISO 1127RA21.326.933.742.048.360.3
Wall thickness pipe ISO 1127a2.02.02.02.02.02.0
Outside pipe-Ø ASTM A312RA21.3426.6733.4-48.2660.33
Wall thickness pipe ASTM A312adimensions acc. to S10 or S40
Socket depthb101313131316
Handwheel-ØB100100100125125125
LengthL506580809090
Wrench size across flatsS1 777101010
Wrench size across flatsS2 303030363636
Weightca. kg1.01.31.73.13.36.0
Kvs-Valuem³/h6.010.517.232.035.057.0
Cv-Valuegal/min7.012.220.037.240.766.3
Dimensions in mm.